Instructions for Replacing FIL16 and FIL32 whole house cartridges
Product Codes: FIL16S | FIL32S | FIL16C | FIL32C
How to Replace Your Cartridge
1) Locate the correct housing ie with code FIL16 or FIL32
2) Turn off the water supply.
3) Take a bucket and place it under the filter housing to catch any water spillage.
4) Then press the red or black button on top of the housing unit (if you have one) to release pressure. Otherwise open up the cold water kitchen tap.
5) Remove the bottom housing from the head (Lefty loosey / righty tighty!)
6) Remove the cartridge
Discard the used cartridge (you can return it to us for recycling, later when it’s dried out).
7) Place the new cartridge in the housing - noting the top and bottom correctly. And make sure it is seated correctly in the bottom slot. Do not unscrew the White lid on the cartridge.
Carefully guide the top of the cartridge up into the centering slot making sure you guide it carefully past any centralising prongs.
10) Close housing unit.
Once you are sure the cartridge is seated correctly inside the housing, tighten it by hand, then use the wrench to tighten it reasonably - don’t overtighten.
Optionally, before closing put some Vaseline around the large black rubber orings to lubricate them. You can also dab some on the screw threads to make it easier to open next time (but do not put Vaseline on the cartridges).
Note re Blue Head / White Bottom style Housings: A fully closed housing has a gap of 2mm to 3mm max between the lower blue nut and the blue top. You can get fairly close to this gap screwing it by hand. Then use the wrench to give it a final tightening. BUT if you need to use a lot of force with the wrench to achieve that 2mm / 3mm then there is a problem. If so check the internal cartridge is inserted correctly.
Note re Black Head / Blue bottom style Housings: When closing the housing up, watch out for the prongs / guides under the black header unit. A loose cartridge might mis-align and be damaged / pierced by them.
When closed turn the water supply back on. (If you have a bypass valve make sure it is turned back on).
Open up your cold water taps for 5 minutes and flush toilets to let any trapped air escape.
The water may look cloudy for a while but will settle down.
Any Problems? Please Telephone 020 8761 6611
Important Note re Reminders
To avoid long term bacteria build-up it is important to change or disconnect your water filter cartridges on time.
We will email you reminders when it's time to change, but please make sure you whitelist our email address so these reminders aren't sent to spam.
And/ or set an alarm now on your mobile or use Siri etc
Please note your feedback and any suggestions as to how we can improve our service are always appreciated.
Thank you
Sales Admin Team
Telephone 020 8761 6611
Water Filter instructions / Guides for fitting and installing
FREE SUPPORT
Need advice?
Please call us on
020 8761 6611
UK Water Filters Ltd
Unit D120
Parkhall Industrial Centre
London
SE21 8DE
UK Water Filters Ltd a Company Limited by Guarantee,
Registered in England,
Company Number: 05249436,
VAT Reg. No. 863 7634 91
Questions? Call us for friendly advice
+44 (0) 20 8761 6611